Every Degree. Every Mile. Every Load.
Climate-locked freight for precision machinery · ±0.4°F guaranteed · Continental US
Fleet Specs
Dual-redundant Thermo King systems. 24-point sensor arrays. Every trailer calibrated to NIST traceable standards before dispatch.
Programmable setpoint across full cargo envelope. Maintained within ±0.4°F regardless of ambient.
Per-trailer sensor grid: 8 ambient, 8 contact, 4 humidity, 4 dew-point probes. Redundant pairs on all axes.
Dual-redundant Thermo King SLXi-400 systems. Primary and standby activate within 0.8 seconds on deviation.
Reinforced floor rated to 48,000 lbs distributed load. Air-ride suspension standard across fleet.
GPS position + full sensor packet transmitted every 90 seconds via dual-carrier cellular. Offline buffer: 72h.
Active climate-locked units. 12 oversized (OD) permitted, 35 standard 53-ft. Dispatch: 24/7/365.
24-Point Climate Array · 53-ft Trailer
Hover sensors to identify. All readings logged at 90-second intervals. Contact sensors mounted on cargo contact points — not ambient air.
Thermal Performance
Route telemetry from HUL-2847: Detroit → Phoenix, Rockies transit. Every data point logged, every deviation documented.
HUL-2847 · Detroit → Phoenix · 2,200 mi
Trailer reaches setpoint ±0.2°F minimum 2 hours before cargo loading. Logged confirmation required.
Door seal integrity test. Sensor baseline logged. Compressor mode set to maintain ±0.4°F envelope.
90-second telemetry packets. Any deviation >0.3°F triggers automated alert to dispatch and client portal.
Full thermal log exported on delivery. Signed chain-of-custody with min/max/avg temp across entire route.
Case Loads
Real loads. Real telemetry. Full chain-of-custody documentation available for all completed shipments.
Mazak Integrex i-400 CNC Lathe
Precision Dynamics Corp — Tucson Plant · Aerospace manufacturing
Spindle bearing tolerance <0.0001". Condensation during Arizona altitude descent would require full recalibration ($180K). Client had 48-hour production window.
Delivered in 31 hours. Peak differential 53.6°F through Rockies. Zero condensation. Spindle calibration intact. Production line started on schedule.
Resources
Quantify your risk exposure before you commit. Download the spec sheet to take to procurement.
Risk-Cost Calculator
Ungated · No signup required
Input your cargo value, route distance, and acceptable temperature range to see estimated risk exposure from uncontrolled transport versus climate-locked haul.
Thermal Transport Spec Sheet
PDF · 14 pages · Updated Feb 2026
Talk to a logistics coordinator
24/7 dispatch · Route quotes in under 4 hours · Fleet availability confirmed same day